Reichert Products

capture

Reichert® 7

Auto Tonometer

Reichert
reichert
reichert
reichert


Reichert 7, Reichert Technologies' seventh generation non-contact tonometer, is the most user friendly NCT ever. With a number of new features, including an easy to navigate touch screen interface and multiple-measurement mode, Reichert 7 will be a welcome addition to your practice. The totally automated operation results in error-free measurements and high patient throughput. Measurement speed and simplicity without sacrificing accuracy.

Features:

  • Alignment is completely automated, no need for joysticks
  • No chinrest or elevation controls necessary – patients simply lean against the forehead rest     (Optional motorized chinrest is available, Catalog Number 16049)
  • Easy-to-use, touch screen user interface
  • One-touch, single or multiple-measurement mode
  • Clearly displays all measurement data
  • Internal printer simplifies record keeping

Multiple-measurement mode:

Reichert 7 features an all-new, one-touch, multiple-measurement mode that delivers 3 or 4 measurements with a single press. This new feature saves time, increases accuracy, and ensures the highest level of comfort for your patients.

User interface:

The touch screen interface features an easy-to-use, icon-based operating system enabling even inexperienced users to make measurements in seconds. The full color display guides the operator through the measurement process showing everything from the alignment of the eye, to the display of the readings. Set up menus and instrument options are also easily accessible and simple to navigate.

Soft puff and quiet operation:

Reichert 7 is designed to make the entire measurement process a comfortable and non-intimidating experience for patients. The instrument features the quietest operation and softest air puff of any NCT available.

Left/Right sliding headrest:

A sliding headrest enables easy patient positioning to ensure fast and comfortable measurements. The operator simply slides the headrest to the left or right position and the patient positions their head against the comfortable headrest pad. Reichert 7 automatically detects which eye is being measured.

Multiple-measurement mode:

Reichert 7 features an all-new, one-touch, multiple-measurement mode that delivers 3 or 4 measurements with a single press. This new feature saves time, increases accuracy, and ensures the highest level of comfort for your patients.

Bright LED array for fast fixation:

The Reichert 7 nosepiece contains an array of bright LEDs. These provide an obvious visual cue to the patient for fast fixation and alignment, thereby reducing exam time.

Accuracy, simplicity, speed:

Operation of Reichert 7 is extremely quick. Patients simply lean against the forehead rest while the operator touches an icon on the screen to activate the fully automated alignment and IOP measurement process. The measurement is taken with speed and simplicity unlike any other NCT, without sacrificing accuracy.

Specifications

Catalog Number:

16050

Weight:

23 lbs., 10.4 kg

Height:

19.75 in., 50.2 cm

Width:

10.5 in., 26.7 cm

Depth:

14 in., 35.6 cm

Voltage:

100-240 VAC

Frequency:

50/60 Hz

Measurement Range:

0 - 60 mmHg  (7 - 60 mmHg ISO 8612 tonometer standard)

Optional Chinrest Specifications:

Catalog Number:

16049

Vertical Travel:

65 mm, motorized

capture

Reichert® 7CR

Auto Tonometer + Corneal Response Technology®

reichert
reichert
reichert
reichert

The Reichert 7CR from Reichert Technologies utilizes a patented bi-directional applanation process to characterize the biomechanical properties of the cornea and reduce their impact on the IOP measurement. This measurement, referred to as Corneal Compensated IOP (IOPcc) is minimally affected by corneal visco-elastic properties, thickness, or surgical procedures such as LASIK or PRK. As such, IOPcc is a better indicator of glaucoma risk than other methods of tonometry, including Goldmann Applanation.

The Reichert 7CR is more clinically valid in all subjects, including: normal tension glaucoma patients, primary open angle glaucoma patients, post-LASIK and refractive surgery patients, patients with Fuchs' or corneal edema, keratoconus patients, and patients with thick, thin, or otherwise biomechanically atypical corneas.

Specifications

Catalog Number:

16060

Weight:

23 lbs., 10.4 kg

Height:

19.75 in., 50.2 cm

Width:

10.5 in., 26.7 cm

Depth:

14 in., 35.6 cm

Voltage:

100-240 VAC

Frequency:

50/60 Hz

Measurement Range:

7 - 60 mmHg (ISO 8612 tonometer standard)

Optional Chinrest Specifications:

Catalog Number:

16049

Vertical Travel:

65 mm, motorized

capture

Tono-Pen AVIA®

Tonometer with Quick-Tap® Measurement Mode

reichert
reichert
reichert
reichert

Tono-Pen® AVIA, now with Quick-Tap® Measurement Mode... More confidence in fewer measurements. Tono-Pen AVIA® Handheld Tonometer is always ready-to-use and calibration-free. An award-winning ergonomic design, long life battery good for thousands of measurements, statistical confidence indicator, and now Quick-Tap® Measurement Mode, make it the most advanced Tono-Pen® yet. The one you trust in tonometry. Designed & assembled in USA.

Tono-Pen AVIA, like the Tono-Pen XL, uses sanitized Ocu-Film® + Tip Covers to minimize the risk of patient cross contamination.

Now Available with Quick-Tap® Measurement Mode.

Select from one of two measurement modes; the traditional First Generation Mode, which provides an IOP measurement typically in five taps, and now the Quick-Tap® Second Generation Measurement Mode where you can obtain a reliable IOP measurement in as few as two taps. This is especially useful for children and less cooperative patients.

reichert

No Calibration Required.

Routine calibration of Tono-Pen AVIA is not required. Spend less time worrying about your instruments and more time with your patients.  

reichert

Award Winning Ergonomic Design.

With its award-winning, ergonomic design and soft-touch grips, the lightweight Tono-Pen AVIA fits comfortably in any operator’s hand, ensuring consistent measurement technique among users.  

reichert

Simple One Button Operation.

To take a measurement, simply press the button once. When the light turns to green, Tono-Pen AVIA is ready to use. Gently tap the anesthetized cornea until a short beep sounds to alert the operator that the measurement is complete.  

reichert

Less Sensitive to Corneal Centration.

Using micro-strain gauge technology, Tono-Pen AVIA is less sensitive to corneal centration than other tonometers and provides fast, accurate, and repeatable results with minimal operator bias.

reichert

Technician Friendly.

Simple one button operation, award winning ergonomics, less sensitivity to corneal centration, and statistical confidence indicator makes delegation of Tono-Pen AVIA to an eye care technician easy and worry-free. Only minimal training is necessary to become proficient in obtaining reliable IOP measurements.

reichert

Gravity Independent.

Unlike most other tonometers, Tono-Pen AVIA can be used in any position, making it easy to measure all patients, including those who may be confined to a wheelchair or bed.

reichert

Large Dual Sided Screens.

The IOP measurement is displayed on two large, easy-to-read, LCD screens making it suitable for both left and right handed users.

reichert

Long-life Battery.

The convenient on-screen battery indicator ensures that Tono-Pen AVIA will always be ready for use. The removable Tono-Pen AVIA POWERCEL® battery pack is easily replaced, requiring no tools. Just squeeze and pull.

reichert

Protect your Patients and your Tono-Pen with genuine Ocu-Film.

Disposable and affordable, single-use, sanitized Reichert Ocu-Film + Tip Covers protect your Tono-Pen, prevent cross contamination, and are easy to apply. Using genuine brand Reichert Ocu-Film + Tip Covers guarantees you are using tip covers that are specifically engineered for proper performance of your Tono-Pen.

Using non-Reichert tip covers may cause Tono-Pen readings to be erratic or inaccurate, and may result in difficulty obtaining measurements. Non-Reichert tip covers may also contaminate the Tono-Pen transducer, potentially voiding the warranty, and resulting in the need for costly service to the instrument.

Reichert Ocu-Film + Tip Covers are FDA cleared and are blue in color to assure the user that the tip cover is the genuine brand approved for use with Tono-Pen AVIA and Tono-Pen XL Applanation Tonometers.

xephilio
capture

Ocular Response Analyzer® G3

Corneal Hysteresis and IOPcc

ocular_response
ocular_response
ocular_response
ocular_response

Corneal Hysteresis: Measure beyond pressure.

Ocular Response Analyzer® (ORA) G3 is the only device that measures Corneal Hysteresis (CH) and Corneal Compensated IOP (IOPcc). Corneal Hysteresis has consistently shown to be a more powerful predictor of, and strongly associated with, glaucoma progression, more so than key risk factors such as IOP and CCT. IOPcc is a pressure measurement that is less affected by corneal properties and more associated with glaucoma risk than Goldmann and other tonometers. Ocular Response Analyzer is engineered, designed, and assembled in USA.

How is Corneal Hysteresis measured?

Corneal Hysteresis is the difference in the inward and outward pressure values obtained during the patented dynamic bi-directional applanation process utilized by the Ocular Response Analyzer. It is a characterization of the cornea’s ability to absorb and dissipate energy, which is a function of visco-elastic biomechanical properties of the cornea.

reichert

Unparalleled user experience.

Measurements could not be quicker or simpler with Ocular Response Analyzer G3. A single touch of the intuitive user interface initiates a fully automated alignment and measurement, simultaneously displaying Corneal Compensated IOP (IOPcc), Corneal Hysteresis (CH), Goldmann correlated IOP (IOPg), and Waveform Score (WS).

ocular_response

Confidence, reliability and efficiency.

The advanced, patent-pending Waveform Score feature, combined with Reichert’s unique intelligent averaging technique, enhances measurement reliability and repeatability so operators can be confident in the accuracy of the measurement results. Operators can easily access all functions through the integrated touch screen display, including export of patient data for effortless EMR integration. Delegate your tonometry and Corneal Hysteresis measurements to trained technicians with ease.

reichert

Non-contact saves time and money.

Because the Ocular Response Analyzer G3 measurement is rapid and non-contact the use of topical anesthesia and/or fluorescein drops is not required, saving time and money. In addition, the risk of cross contamination is greatly reduced. The need for time-consuming sterilization of tonometer prisms, costly replacement of prisms, or use of expensive disposables is eliminated.

reichert

Unique design with patients in mind.

Ocular Response Analyzer G3 is designed with no chinrest, which saves time by simplifying patient positioning. This unique design also makes patients more comfortable and less intimidated by not feeling confined in a chinrest.

reichert

Patented air pulse, maximum comfort.

Reichert’s automatic, non-linear pressure ramp customizes the air pulse, in real time, for each eye being measured. This patented feature enables the softest possible air pulse, ensuring maximum patient comfort. In a pediatric study conducted on children between the ages of 4-18 years old found, “Overall cooperation was much better with ORA (89.8%) than with Goldmann applanation (78.7%), and all the children we questioned preferred this (ORA) technique.”7

reichert